Acu Rite Clock 984 User Manual

00984 Wireless Thermometer & Hygrometer  
Remote Sensor  
TROUBLESHOOTING:  
The main unit may display “---” if the signal is being interrupted by outside interference.  
In most cases, the unit will re-sync with the remote sensor on it’s own. It may also help to  
bring the remote sensor closer to the main unit to re-sync the main unit and the remote  
sensor. However, should this condition continue to occur, be sure to check the following:  
Fig. 1  
A. The batteries may be low, replace and repeat setup procedure.  
B. The sensor may be placed outside of the effective transmission range (100 feet).  
C. The sensor may have outside interference that is preventing transmission.  
( metal surfaces, other electronic devices, etc.). The sensor may need to be moved to  
another location if interference continues.  
1
F
86.5  
THERMO HYGRO  
To access the battery  
compartment and the  
function buttons, open  
the case along the seam.  
FRONT  
BACK  
Do not return product to retail store.  
For Technical Assistance and product return information,  
please call Chaney Instrument Co. direct at:  
Acu-Rite instruments have been designed and engineered to provide accurate and reliable  
Measurements. Please read the instructions thoroughly before setting up your wireless  
thermometer.  
877-221-1252  
The remote sensor is designed to stand or hang. For wall mounting, use the enclosed screw  
to mount to the desired surface. Use the slot on the back of the case to mount the remote  
sensor to the surface.  
Remote Sensor Features:  
• The remote sensor can transmit up to 100 feet  
• The remote sensor has a weather resistant case. Keep the unit out of direct sunlight and  
direct weather conditions. This will extend the life of the unit.  
• The remote sensor has a temperature measurement range of -4ºF to 122ºF / 0ºC to 50ºC  
and a humidity measurement range of 20% to 99%.  
NOTE: Severe cold weather can cause alkaline batteries to freeze and stop functioning  
properly. Lithium batteries are required for temperatures below -12ºF / -24ºC.  
1
Battery Installation and Setup:  
For installation, insert batteries in the main unit first, then install batteries in the remote  
sensor unit second.  
To install batteries in the remote sensor unit, refer to figure 1 on page 1 for visual reference.  
Gently open the case along the seam separating the front and back halves. Insert two  
AAA(1.5v) batteries according to the diagram in the battery compartment.  
Next, select a channel to use with the channel selection switch. You may use up to 3 remote  
sensors with the 00592W and the 00593W main units. Your new RF remote sensor is built  
with random security code technology. The main unit will learn the random security code of  
the remote sensor and will be registered without being interfered with by a neighbor who  
may be using the same type of sensor under the same channel setting.  
CHANNEL  
Press the “TX” button located above the battery compartment to send a signal to the  
main unit. The main unit will then receive the signal from the remote sensor and log the  
random signal code in as the same channel you selected on the remote sensor.  
To link additional wireless remote sensor units to the main unit, repeat the above steps  
TX C/F MODE  
1 2 3  
AAA 1.5v  
AAA 1.5v  
Fahrenheit or Celsius Setup:  
To select between Fahrenheit or Celsius temperature display on the remote sensor display,  
push the “C/F” button located inside the case above the battery compartment.  
Mode Selection:  
The mode button allows you to select between different display modes on the remote sensors  
built-in display. The default display mode when you first install the batteries is to show the  
temperature. You may press the “MODE” button once to change to humidity display, or press  
the “MODE” button a third time to move to an alternating display which shows the temp.  
BACK (inside the case)  
and humidity in an alternating format. A small icon will appear on the screen (  
) to signify  
that you are in the alternating display mode. If you press the “MODE” button a fourth time,  
you will return back to the default temperature display mode.  
Additional Remote Sensor Placement Suggestions:  
Additional sensors can be purchased separately, Acu-rite model #00984  
• Outside your home or place of business  
• Wine cellars  
• In the garage  
• Childrens room  
CLOSE THE CASE BY PRESSING THE FRONT AND BACK TOGETHER FIRMLY.  
Replacing Batteries:  
When replacing batteries in the remote sensor unit, the channel logged in the main unit  
must be cleared. Follow the appropriate main unit instructions on channel selection.  
To reset the entire unit, remove the batteries in the main unit and the remote sensor(s) and  
the registered channel(s) will be erased. Follow the thermometer set-up procedures as  
outlined in the appropriate main unit instruction manual and this remote sensor manual.  
• Gardens or greenhouses  
• Any location that remote temperature readings are beneficial  
To order more sensors by phone, please call Klock-it at 800-556-2548  
2
3

Motorola XT926M User Manual
JVC KD LH3105 User Manual
Jura Capresso IMPRESSA F505 User Manual
IOGear ION Drive GHE225U40 User Manual
HTC Touch HD BLAC100 User Manual
Hamilton Beach 49464 User Manual
Disney DCR5500 C User Manual
Dakota Digital MAN #650134 User Manual
Bloomfield 2272 User Manual
Adobe ADBCD17648MC User Manual