Frigidaire Cooktop RC30G60PS User Manual

Built-In Downdraft Cooktop  
RC30DG60PS  
30" Gas  
Product Dimensions  
Width  
30"  
Depth  
21-13/32"  
Height (Min.)/(Max.)  
17-13/16"/ꢀ23-3/8"  
More Easy-To-Use Features  
Low Simmer Burner  
Perfect for delicate foods and sauces.  
Stainless Steel Recessed Cooktop  
3 Ducting Options  
Dishwasher-Safe Filter  
Available in:  
Stainless  
(S)  
Burners  
BTU  
Right Front  
Right Rear  
Left Front  
Left Rear  
12,000  
5,000  
9,500  
17,000  
Signature Features  
Downdraft System  
PowerPlus® Boil  
17,000 BTU sealed burner boils  
water faster.  
Whisks away odors and smoke without  
the need for overhead ventilation.  
Pro-Select® Controls  
Continuous Grates  
Precise control at your fingertips.  
Continuous grates make it easy to  
move heavy pots and pans between  
burners without lifting.  
frigidaire.com  
 
Built-In Downdraft Cooktop  
RC30DG60PS 30" Gas  
30" Gas Cooktop  
with Ventilation Unit  
For ventilation unit ductwork preparation  
and installation planning information, refer to  
30" min. for  
30" Gas Cooktop Ductwork Preparation page.  
unprotected  
30"  
cabinet bottom  
24" min.  
Rear Discharge  
Right Side View  
for protected  
cabinet bottom  
18"  
min.  
2113/32"  
30"  
1713/16"  
13"  
max.  
cabinet  
depth  
Ventilation  
unit not shown  
beneath cooktop.  
311/16"  
2613/16"  
1815/16"  
Down Discharge  
Right Side View  
13/8" minimum flat distance  
from cutout edge  
28"  
191/8  
"
9" min. to nearest  
combustible wall  
(each side of unit)  
233/8  
"
24"  
13/8" minimum flat distance  
from cutout edge  
Built-In Cooktop Specifications  
Cooktop Shipping Weight (approx.) – 89 Lbs.  
Voltage Rating – 120Vꢀ/ꢀ60 Hzꢀ/ꢀ15 Amps  
For use on adequately wired 120V, dedicated circuit having 2-wire  
service with a separate ground wire. Appliance must be grounded  
for safe operation.  
Amps @ 120 Volts = 15  
Always consult local and national electric and gas codes.  
For detailed electrical and gas supply locations, refer to  
30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.  
Locate cooktop between wall studs or floor joists so that ductwork  
may be installed properly.  
Installing cooktop into pre-existing base cabinets may require  
modifications. Cabinets with drawers require drawers be removed  
and drawer fronts attached to cabinet face. Verify internal length  
and width of cabinet base because sides or back wall may need  
cut out and corner braces removed to accommodate unit.  
Countertop opening MUST be cut based on dimensions shown,  
cut squarely with sides parallel to each other and with front and  
rear perpendicular to cabinet sides.  
Provide adequate gas supply. Cooktop ships with 3/4" factory  
regulator.  
LP Gas conversion kit supplied.  
Overhead cabinetry should not exceed a 13" maximum depth.  
Absolute minimum horizontal distance between overhead cabinets  
installed to either side of appliance must be no less than 36".  
Allow 30" minimum clearance between top of cooktop platform  
and bottom of unprotected wood or metal overhead cabinet.  
Allow 9" minimum required clearance from left edge and right edge  
of cooktop to nearest combustible wall on each side.  
Ductwork Preparation  
For ventilation unit ductwork preparation and planning information,  
refer to 30" Gas Cooktop (RC30DG60P) Ductwork Preparation page.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.  
Optional Accessories  
Granite Countertop Installation Kit – (PN # 903103-9010)  
Pre-formed countertops with raised lip and radius at base of  
backsplash may not allow enough flat area for proper installation.  
Minimum 1-3/8" distance required from rear and front edge of  
cooktop cutout.  
Accessories information available  
on the web at frigidaire.com  
USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com  
Specifications  
subject to change.  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca  
RC30DG60P 07/13  
Download from Www.©So20m13aEnluecatlrso.lcuxomHo.mAellPMroaduncutsa,lIsncS. earch And Download.  
Built-In Downdraft Cooktop  
RC30DG60PS 30" Gas  
Electrical /Gas Supply Location  
30" Gas Downdraft Cooktop –  
Ductwork Preparation  
Countertop  
surface  
51/2  
"
Ventilation unit comes detached from cooktop.  
C
Cabinet  
side wall  
L
Cabinet  
side wall  
To ensure proper installation, refer to 30" Gas Downdraft  
Cooktop Specifications page for planning information, and  
installation guide on web for complete installation details  
including countertop and cabinet requirements.  
Electrical  
Installation Note:  
31/4  
"
Recomm.  
gas supply  
stub area  
Locate 120 volt,  
60 Hertz, properly  
grounded branch  
circuit protected  
by 15 amp circuit  
breaker or time  
delay fuse within  
shaded area  
Ducting Options  
On floor, through floor or through wall.  
4"  
4"  
11"  
shown.  
45/16"  
Exhaust Outlet Locations –  
Cut exhaust outlet hole in wall or  
floor based on desired installation.  
Exhaust duct MUST be located  
between wall studs or floor joists.  
Cutout  
center  
Cutout  
center  
8"  
6"  
6"  
71/8  
"
45/16"  
Bottom  
Exhaust Outlet  
Rear Wall  
Exhaust Outlet  
Built-In Cooktop Ductwork Preparation  
Ventilation unit comes detached from cooktop. To ensure proper  
For maximum efficiency, use shortest, straightest duct run possible.  
Unit operates most efficiently with up to 100 equivalent feet of duct.  
(Refer to Calculating Duct Length Table in Product Installation Guide.)  
Flexible ducting is not recommended due to severely restricted  
airflow; if blower outlet and floor or wall duct location do NOT align,  
flexible METAL ducting can be used to adapt to offset.  
Thermal breaks such as short section of nonmetallic duct, should  
be used in areas of extreme cold. Cold weather installations should  
have additional backdraft damper installed.  
installation, refer to 30" Gas Downdraft Cooktop Specifications page  
for planning information, and installation guide on web for complete  
installation details including countertop and cabinet requirements.  
Ducting Options – On floor, through floor or through wall.  
Ventilation Unit Discharge Options – Rear or down.  
Consider ductwork location and desired installation before cutting  
exhaust outlet hole in cabinet. For proper installation, cooktop  
exhaust duct MUST be located between wall studs or floor joists.  
Vent exhaust air outside only and NOT into any concealed space.  
Note: For planning purposes only. Refer to Product Installation Guide  
on the web at frigidaire.com for detailed instructions.  
Exhaust Duct Required – Galvanized or aluminum duct in 6" round  
or 3-1/4" x 10" rectangular, or combination of both. PVC should  
be used if installing under concrete slab.  
Local building code must be followed in specifying approved type  
and schedule of ALL duct used; always use appropriate roof or  
wall cap with damper.  
Accessories information available  
on the web at frigidaire.com  
USA 10200 David Taylor Drive Charlotte, NC 28262 1-800-FRIGIDAIRE frigidaire.com  
Specifications  
subject to change.  
CANADA 5855 Terry Fox Way Mississauga, ON L5V 3E4 1-800-265-8352 frigidaire.ca  
RC30DG60P 07/13  
Download from Www.©So20m13aEnluecatlrso.lcuxomHo.mAellPMroaduncutsa,lIsncS. earch And Download.  

Cortelco Cordless Telephone 730901 TP2 27F User Manual
Crate Amplifiers Stereo Amplifier CA120D User Manual
Crown Equipment Automobile B Series User Manual
Desa Water Heater CGP10TA User Manual
Digi Switch 910H User Manual
DigiTech Musical Toy Instrument JamMan Express XT User Manual
Electro Voice Music Mixer Elan Series User Manual
Everpure Water System EV9318 50 User Manual
GE Air Conditioner AZ29E09EAC User Manual
GE Oven JKP15 User Manual